When a PE piping system is to be operated at a constant temperature higher than 2o°, up to and including 50°, a pressure reduction needs to be applied to maintain all specifications.
Temperature | Coefficient |
---|---|
20 °C | 1.00 |
25 °C | 0.92 |
30 °C | 0.85 |
35 °C | 0.79 |
40 °C | 0.73 |
45 °C | 0.67 |
50 °C | 0.62 |